Part Number Hot Search : 
SB100 BPC5010 4HC40 DDU4F HX2019NL R05C15 10004 Y7C13
Product Description
Full Text Search
 

To Download AWS5522 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 AWS5522
0.5 to 2.5 GHz SPDT Switch
ADVANCED PRODUCT INFORMATION - Rev 0.1
FEATURES
* * * * * Low Insertion Loss: 0.5 dB at 2 GHz High Isolation: > 25 dB Low Harmonic Levels: < -65 dBc Low Control Voltage Operation: to +2.5 V Low Profile Surface Mount Package
AW
S55
22
APPLICATIONS
* * GSM Wireless Handsets and Front-end Modules CDMA Wireless Handsets and Front-end Modules
D1 Die
S26 Package 12 Pin MLF 3mm x 3mm
PRODUCT DESCRIPTION
The AWS5522 is a single pole, double throw (SPDT) RF switch developed to meet the stringent requirements of GSM and CDMA systems. Manufactured in ANADIGICS's state-of-the-art pHEMT process, the device uses patent-pending circuit topologies to provide the low insertion loss, high port-to-port isolation and high linearity needed to enhance the performance of wireless handset radios. The AWS5522 is offered both as an MMIC die and in a 12-lead 3mm x 3mm MLF package.
VS1
RFC
VS2
RF1
RF2
RF1G
V1
V2
RF2G
Figure 1: Block Diagram
12/2002
AWS5522
Table 1 : Pad Description NAME
RF1 VS1
DESCRIPTION Common port bias voltage (logic high) RF port, path 1 Ground Control voltage, RF path 1 Control voltage, RF path 2 Ground RF port, path 2 Common port bias voltage (logic high) RF common port
VS1
RF1G
RF1 RF1G
V1 RFC V2
V1 V2
RF2G
RF2G RF2
RF2 VS2
VS2 RFC
Dimensions in m. Bond Pads: 100m x75m Die Thickness: 178m No backside metal.
Figure 2 : Die Configuration
Table 2: Pin Description PIN
NC RFC VS2 12 11 10
NAME RF1 V1
DESCRIPTION RF port, path 1 Control voltage, RF path 1 Control voltage, RF path 2 RF port, path 2 Common port bias Voltage (logic high) RF common port Ground No connection
2 4
NC RF1 GND
1 2 3
9 8 7
NC RF2 GND
6 8 10
V2 RF2 VS2 RFC GND NC
4
5
6 V2
V1 NC
11 3, 7 1, 5, 9, 12
Figure 3: Packaged Device Pinout (X-ray Top View)
2
ADVANCED PRODUCT INFORMATION - Rev 0.1 12/2002
AWS5522
ELECTRICAL CHARACTERISTICS
Table 3: Absolute Minimum and Maximum Ratings PARAMETER Common Port Bias Voltage (VS) Control Voltages (V1, V2) RF Input Power (PIN) Storage Temperature (2) MIN -0.2 -0.2 -65 MAX +8.0 +8.0 10 +150 UNIT V V W C at RF1, RF2 and RFC COMMENTS at VS1 or VS2 (1)
Stresses in excess of the absolute ratings may cause permanent damage. Functional operation is not implied under these conditions. Exposure to absolute ratings for extended periods of time may adversely affect reliability. Notes: (1) The VS1 and VS2 ports may remain open-circuited without damage to the device. (2) Storage Temperature limits apply to the die only after it has been removed from the ANADIGICS shipping material. (The limits apply at all times for the packaged device.) 3. The RF1, RF2 and RFC ports should be AC-coupled. No external DC bias should be applied.
Table 4: Operating Ranges PARAMETER RF Frequency (f) Common Port Bias Voltage (VS) Control Voltages (V1, V2) Ambient Temperature (TA) 0 +2.5 -30 MIN 0.5 TYP (1)
MAX 2.5
UNIT GHz
COMMENTS
applied at either VS1 or VS2 port +0.2 +3.5 +85 V C RF path OFF state RF path ON state
-
The device may be operated safely over these conditions; however, parametric performance is guaranteed only over the conditions defined in the electrical specifications. Notes: (1) For optimal linearity performance, the Common Port Bias Voltage (VS) should be set to the same Control Voltage used to turn ON either of the individual RF paths. The VS1 and VS2 ports may remain open-circuited without damage to the device, but with some degradation in linearity.
ADVANCED PRODUCT INFORMATION - Rev 0.1 12/2002
3
AWS5522
Table 5: Electrical Specifications - Unpackaged Die (TA = +25 C; RF ports terminated with 50 ; Vn = +2.7 V and is the Control Voltage for the ON path, RFC-RFn; Vx = 0 V and is the Control Voltage for the OFF path, RFC-RFx) PARAMETER Insertion Loss 1 GHz 2 GHz Return Loss (1) 1 GHz 2 GHz Isolation 1 GHz 2 GHz Input Third Order Intercept (2) 800 MHz Cellular Band 1900 MHz PCS Band 2nd Harmonic Rejection (3) 1 GHz 2 GHz 3rd Harmonic Rejection (3) 1 GHz 2 GHz Current Consumption MIN TYP 0.4 0.5 MAX 0.6 0.8 UNIT dB COMMENTS RFC port to selected RFn port
-
-30 -32
-20 -20
dB
RFC port and selected RFn port
25 25
27 27
-
dB
RFC port to isolated RFx port
-
+60 +59
-
dBm
RFC port to selected RFn port
-
-79 -78
-65 -65
dBc
PIN = +34 dBm PIN = +32 dBm
-
-88 -81 -
-65 -65 30 5
dBc A A
PIN = +34 dBm PIN = +32 dBm each Vn port VS1 or VS2 port
Notes: (1) The isolated RFx port has a return loss of approximately -3 dB. (2) For the Cellular Band, two tones with PIN = +22.5 dBm each, at 900.0 and 900.1 MHz. For the PCS Band, two tones with PIN = +21 dBm each, at 1900.0 and 1900.1 MHz. (3) Vs = Vn
Table 6: Switch Control Truth Table CONTROL VOLTAGES V1 +2.5 to +3.5 V 0 to +0.2 V V2 0 to +0.2 V +2.5 to +3.5V RF PATH SELECTION RFC - RF1 ON OFF RFC - RF2 OFF ON
4
ADVANCED PRODUCT INFORMATION - Rev 0.1 12/2002
AWS5522
Table 7: Electrical Specifications - Packaged Device (TA = +25 C; RF ports terminated with 50 ; Vn = +2.7 V and is the Control Voltage for the ON path, RFC-RFn; Vx = 0 V and is the Control Voltage for the OFF path, RFC-RFx) PARAMETER Insertion Loss 1 GHz 2 GHz Return Loss (1) 1 GHz 2 GHz Isolation 1 GHz 2 GHz Input Third Order Intercept (2) 800 MHz Cellular Band 1900 MHz PCS Band 2nd Harmonic Rejection (3) 1 GHz 2 GHz 3rd Harmonic Rejection (3) 1 GHz 2 GHz Current Consumption MIN TYP 0.4 0.5 MAX -0.6 -0.8 UNIT dB COMMENTS RFC port to selected RFn port
-
-28 -33
-20 -20
dB
RFC port and selected RFn port
25 25
27 27
-
dB
RFC port to isolated RFx port
-
+60 +59
-
dBm
RFC port to selected RFn port
-
-75 -76
-65 -65
dBc
PIN = +34 dBm PIN = +32 dBm
-
-70 -74 -
-65 -65 30 5
dBc A A
PIN = +34 dBm PIN = +32 dBm each Vn port VS2 port
Notes: (1) The isolated RFx port has a return loss of approximately -3 dB. (2) For the Cellular Band, two tones with PIN = +22.5 dBm each, at 900.0 and 900.1 MHz. For the PCS Band, two tones with PIN = +21 dBm each, at 1900.0 and 1900.1 MHz. (3) Vs = Vn
ADVANCED PRODUCT INFORMATION - Rev 0.1 12/2002
5
AWS5522
PERFORMANCE DATA
Figure 4: Insertion Loss vs. Frequency Unpackaged Die (ON path, Vn = +2.7 V, Vx = 0 V)
0
Figure 5: Insertion Loss vs. Frequency Packaged Device (ON path, Vn = +2.7 V, Vx = 0 V)
0
-0.2
-0.2
Insertion Loss (dB)
1000 1500 2000 2500
Insertion Loss (dB)
-0.4
-0.4
-0.6
-0.6
-0.8
-0.8
-1 500
-1 500
1000
1500
2000
2500
Frequency (MHz)
Frequency (MHz)
Figure 6: Return Loss vs. Frequency Upackaged Die (ON path, Vn = +2.7 V, Vx = 0 V)
0 RFC port RFn port -10
Figure 7: Return Loss vs. Frequency Packaged Device (ON path, Vn = +2.7 V, Vx = 0 V)
0 RFC port RFn port -10
-20
Return Loss (dB)
1000 1500 2000 2500
Return Loss (dB)
-20
-30
-30
-40
-40
-50 500
-50 500
1000
1500
2000
2500
Frequency (MHz)
Frequency (MHz)
Figure 8: Isolation vs. Frequency Unpackaged Die (OFF path, Vn = +2.7 V, Vx = 0 V)
0
Figure 9: Isolation vs. Frequency Packaged Device (OFF path, Vn = +2.7 V, Vx = 0 V)
0
-10
-10
-20
Isolation (dB)
1000 1500 2000 2500
Isolation (dB)
-20
-30
-30
-40
-40
-50 500
-50 500
1000
1500
2000
2500
Frequency (MHz)
Frequency (MHz)
6
ADVANCED PRODUCT INFORMATION - Rev 0.1 12/2002
AWS5522
Figure 10: Harmonics of 1 GHz vs. Control Voltage Unpackaged Die (ON path, Vx = 0 V, f = 1 GHz, PIN = +34 dBm)
-30 2nd Harmonic, Vs open 2nd Harmonic, Vs = Vn 3rd Harmonic, Vs open 3rd Harmonic, Vs = Vn
Figure 11: Harmonics of 1 GHz vs. Control Voltage Packaged Device (ON path, Vx = 0 V, f = 1 GHz, PIN = +34 dBm)
-30 2nd Harmonic, Vs open 2nd Harmonic, Vs = Vn 3rd Harmonic, Vs open 3rd Harmonic, Vs = Vn
-40
-40
Harmonic Level (dBc)
-60
Harmonic Level (dBc)
2.5 2.6 2.7 2.8 2.9 3 3.1 3.2 3.3 3.4 3.5
-50
-50
-60
-70
-70
-80
-80
-90
-90
-100
-100 2.5 2.6 2.7 2.8 2.9 3 3.1 3.2 3.3 3.4 3.5
Control Voltage (V)
Control Voltage (V)
Figure 12: Harmonics of 2 GHz vs. Control Voltage Unpackaged Die (ON path, Vx = 0 V, f = 2 GHz, PIN = +32 dBm)
-30 2nd Harmonic, Vs open 2nd Harmonic, Vs = Vn 3rd Harmonic, Vs open 3rd Harmonic, Vs = Vn
Figure 13: Harmonics of 2 GHz vs. Control Voltage Packaged Device (ON path, Vx = 0 V, f = 2 GHz, PIN = +32 dBm)
-30 2nd Harmonic, Vs open 2nd Harmonic, Vs = Vn 3rd Harmonic, Vs open 3rd Harmonic, Vs = Vn
-40
-40
Harmonic Level (dBc)
-60
Harmonic Level (dBc)
2.5 2.6 2.7 2.8 2.9 3 3.1 3.2 3.3 3.4 3.5
-50
-50
-60
-70
-70
-80
-80
-90
-90
-100
-100 2.5 2.6 2.7 2.8 2.9 3 3.1 3.2 3.3 3.4 3.5
Control Voltage (V)
Control Voltage (V)
ADVANCED PRODUCT INFORMATION - Rev 0.1 12/2002
7
AWS5522
APPLICATION INFORMATION
Unpackaged Die Applications Bonding and circuit connections for the unpackaged AWS5522 die are shown in Figure 14, and application details are listed in the following notes: 1. Cb are DC blocking capacitors external to the device. A value of 100pF is sufficient for operation to 500MHz. The values may be tailored to provide specific electrical responses. The isolation of the switch provides enough decoupling of the RF1 and RF2 ports so that overall switch performance is not affected. 2. The VS1 and VS2 pins provides a fixed voltage potential to the common port of the switch. To get the best linear performance, either VS1 or VS2 should be tied to the logic high voltage potential (not the power supply). Only one of these pins need be attached, with the decision determined by external circuit layout. Current draw on this pin is less than 5A.
3. The RF Ground bondwires should be kept as short as possible and bonded directly to a good RF ground for best broadband performance. 4. LESD provides a means to increase the ESD protection on a specific RF port, typically the port attached to the antenna. The ESD rating of the device is 125V HBM overall. This rating is associated with the control pin to RF port path. RF port to RF port/RF Gnd has been determined to be >500V HBM for this technology. By using LESD as an RF choke on a port, an ESD protection to 8kV contact discharge can be achieved. 5. The die may be attached by either conductive or non-conductive epoxy formulated for attaching semiconductor parts. The back of the die is electrically isolated from the switch circuit and can be grounded or left isolated.
Common (Ant.) RF Port LESD
Note 4
Cb Common Port Supply
Note 2 (Logic high)
Cb RF Port 1
VS1 RF1
RFC
VS2 RF2
Cb RF Port 2
RF1G
V1
V2
RF2G
Keep RF Gnd Bondwires Short
2 Places, Note 3
RF Gnd, Path 1 Shunt Control Pin, RF Path 1
RF Gnd, Path 2 Shunt Control Pin, RF Path 2
Figure 14: Unpackaged Die Application Schematic
8
ADVANCED PRODUCT INFORMATION - Rev 0.1 12/2002
AWS5522
Packaged Device Applications External component requirements for the packaged AWS5522 device are shown in Figure 15, and application details are listed in the following notes: 1. Cb are DC blocking capacitors external to the device. A value of 100pF is sufficient for operation to 500MHz. The values may be tailored to provide specific electrical responses. The isolation of the switch provides enough decoupling of the RF1 and RF2 ports so that overall switch performance is not affected. 2. The VS2 pin provides a fixed voltage potential to the common port of the switch. To get the best linear performance, VS2 should be tied to the logic high voltage potential (not the power supply). Current draw on this pin is less than 5A.
3. The RF Ground connections should be kept as short as possible and tied directly to a good RF ground for best broadband performance. 4. LESD provides a means to increase the ESD protection on a specific RF port, typically the port attached to the antenna. The ESD rating of the device is 125V HBM overall. This rating is associated with the control pin to RF port path. RF port to RF port/RF Gnd has been determined to be >500V HBM for this technology. By using LESD as an RF choke on a port, an ESD protection to 8kV contact discharge can be achieved. 5. The large pad on the bottom of the package should be soldered to ground to assure proper performance of the device.
Common (Ant.) RF Port
LESD
Note 4
Cb Common Port Supply
RFC
Note 2 (Logic high)
NC 12
11
10
NC
VS2
1
9
NC
Cb RF Port 1 RF Gnd, Path 1 Shunt
RF1 2 8 RF2
Cb RF Port 2 RF Gnd, Path 2 Shunt
3
7
4
V1
5 NC
6
V2
Keep RF Gnd Connection Short
2 Places, Note 3
Control Pin, RF Path 1
Control Pin, RF Path 2
Figure 15: Packaged Device Application Schematic
ADVANCED PRODUCT INFORMATION - Rev 0.1 12/2002
9
AWS5522
PACKAGE OUTLINE
7. 2X 0.15 A D 0.20 DIA. CA A
0.08
C D1
A3 A1
b 5. 6.
0.10 M C A B PIN #1 ID R0.20
0.48 TYP.
4.
2X 0.15 CB
1 2 3 E
1 2 3 L C SEATING PLANE e E
B
TOP VIEW
BOTTOM VIEW
NOTES :
S Y M B O L S Y M B O L
DIMENSIONS-MM NOM. MAX. MIN.
0.80 0.00 0.18 1.45 1.45 0.35 0.85 0.01 0.20 REF. 0.23 3.00 BSC 1.60 3.00 BSC 1.60 0.50 BSC 0.40 1.00 0.05 0.30 1.75 1.75 0.55
N O T E
DIMENSIONS-INCHES MIN. NOM. MAX.
0.031 0.000 0.007 0.057 0.057 0.014 0.033 0.0003 0.008 0.009 0.118 BSC 0.063 0.118 BSC 0.063 0.019 BSC 0.016 0.039 0.001 0.011 0.069 0.069 0.022
N O T E
1. ALL DIMENSIONS ARE IN MILLIMETERS. 2. MAX. PACKAGE WARPAGE IS 0.05 mm. 3. MAXIMUM ALLOWABLE BURRS IS 0.076 mm IN ALL DIRECTIONS. 4. PIN #1 ID ON TOP WILL BE LASER/INK MARKED. 5. APPLIED ONLY FOR TERMINALS 6. DIMENSION b APPLIES TO METALLIZED TERMINAL AND IS MEASURED BETWEEN 0.20 AND 0.25mm FROM TERMINAL TIP. 7. APPLIED FOR EXPOSED PAD AND TERMINALS. EXCLUDE EMBEDDING EXPOSED PART FROM MEASURING. 8. REFERENCE JEDEC OUTLINE MO-220.
A A1 A3 b D D1 E E1 e L
A A1 A3 b D D1 E E1 e L
Figure 16: S26 Package Outline - 12 Pin 3mm x 3mm MLF
P8_2035
10
ADVANCED PRODUCT INFORMATION - Rev 0.1 12/2002
AWS5522
NOTES
ADVANCED PRODUCT INFORMATION - Rev 0.1 12/2002
11
AWS5522
ORDERING INFORMATION
ORDER NUMBER AWS5522D1 AWS5522S26 TEMPERATURE RANGE -30 C to +85 C -30 C to +85 C PACKAGE DESCRIPTION Die 12 Pin 3mm x 3mm MLF COMPONENT PACKAGING (contact ANADIGICS for details) Tape & Reel
ANADIGICS, Inc.
141 Mount Bethel Road Warren, New Jersey 07059, U.S.A. Tel: +1 (908) 668-5000 Fax: +1 (908) 668-5132 URL: http://www.anadigics.com E-mail: Mktg@anadigics.com IMPORTANT NOTICE
ANADIGICS, Inc. reserves the right to make changes to its products or to discontinue any product at any time without notice. The product specifications contained in Advanced Product Information sheets and Preliminary Data Sheets are subject to change prior to a product's formal introduction. Information in Data Sheets have been carefully checked and are assumed to be reliable; however, ANADIGICS assumes no responsibilities for inaccuracies. ANADIGICS strongly urges customers to verify that the information they are using is current before placing orders.
WARNING
ANADIGICS products are not intended for use in life support appliances, devices or systems. Use of an ANADIGICS product in any such application without written consent is prohibited.
12
ADVANCED PRODUCT INFORMATION - Rev 0.1 12/2002


▲Up To Search▲   

 
Price & Availability of AWS5522

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X